Subject: Re: GEN MILLE4Q10 < Refurbishaed Gen >
In-Reply-To: <GV1PR05MB97716C022C0F8E094677A193B3B6A@GV1PR05MB9771.eurprd05.prod.outlook.com>
References: <PR2PR08MB4876880197B921D32BAF15DB99A9A@PR2PR08MB4876.eurprd08.prod.outlook.com>
 <AS8PR05MB85663ABC7E0CD95B55D8049A93A9A@AS8PR05MB8566.eurprd05.prod.outlook.com>
 <GV1PR05MB97716C022C0F8E094677A193B3B6A@GV1PR05MB9771.eurprd05.prod.outlook.com>
Message-ID: <141d261ec1aeac6e2240245603628e7f@matech-cameroun.com>
X-Sender: amza.njatono@matech-cameroun.com
X-Priority: 1 (Highest)
Content-Type: text/plain; charset=UTF-8;
 format=flowed
Content-Transfer-Encoding: 8bit

Bonjour Patrick ;

Vous avez soumis un generateur avec un moteur serie 1000 non turboté 
correspondant à une transformation en un 30KVA soumis au refurbish ,  en 
lieu et place d'un moteur serie 1000 turbo correspondant à la fiche 
technique que tu filme sur la coque du générateur.

dites nous concrètement ce que vous souhaitez le budget est 
minutieusement détaillé filmé et bridé et vous l'avez .

Les pièces majeures comme turbo et autres  sortent même de vos scrabs 
parfois remis gratuitement mais sans garanti.

l'idéal est de trouver un vrai 45KVA avec turbo fonctionnel dessus pour 
déployer sur ce site et transféré celui là sur un site moins porteur , 
il fonctionne normalement.

Cordialement

Amza NJATONO
MATECH SARL


Le 2025-12-20 08:08, Patrick Esuma a écrit :
> Hello @MEFIRE PENSOUME IBRAHIM,
> 
>  Bien vouloir prendre en compte ce cas (Gen N58 IPT TRION 45KVA) et y
> apporter une solution urgente. ce site est prioritaire.
> 
>  Bien vouloir partager votre plan d'intervention dans ce site.
> 
>  Best Regards
> -------------------------
> 
>  From: Sani Njamo <sani.njamo@ihstowers.com>
> Sent: Friday, December 19, 2025 2:16 PM
> To: Patrick Esuma <patrick.esuma.ctr@ihstowers.com>
> Cc: Astrid Chigheng Djouassi <astrid.djouassi@ihstowers.com>; Stephane
> Ketchouang <stephane.ketchouang@ihstowers.com>; Francois J. Nsegbe
> <francois.nsegbe@ihstowers.com>; Hugues Tchagou
> <hugues.tchagou@ihstowers.com>
> Subject: Fw: GEN MILLE4Q10 < Refurbishaed Gen >
> 
>  Hi Pat
>  Fwd
> 
>  Best regards
> 
> -------------------------
> 
>  From: Joseph Bertrand Tchouape <jtchouape@ieng-group.com>
> Sent: Friday, December 19, 2025 2:04 PM
> To: Sani Njamo <sani.njamo@ihstowers.com>
> Cc: Stephane Ketchouang <stephane.ketchouang@ihstowers.com>; Francois
> J. Nsegbe <francois.nsegbe@ihstowers.com>; Nasser Tchagna Pondja
> <npondja@ieng-group.com>; Armand Achille Boble
> <bachille.cm@ieng-group.com>; Kameni <ykameni@ieng-group.com>; Cobat
> <cobat@ieng-group.com>; Hugues Tchagou <hugues.tchagou@ihstowers.com>
> Subject: GEN MILLE4Q10
> 
>  CAUTION: This email originated from outside of the organization. Do
> not click links or open attachments unless you recognize the sender
> and know the content is safe.
> 
>  Hi Boss,
> 
>  Le générateur 45kva nouvellement installé à mille4Q10 ne nous
> aide pas.
> 
>  Il est en perte de rendement.
> 
>  Il ne supporte pas la charge du site.
> 
>  Des sons arrive le turbo avais été supprimé.
> 
>  Il s’affaisse avec un courant de 27A 28A 29A Par phase.
> 
>  Alors que les phases sont censées aller jusqu’à 67A par phase.
> 
>  Il sera nécessaire de faire son remplacement enfin de mieux
> stabiliser le site.
> 
>  Region
> 
>  Cluster
> 
>  IHS SITE ID
> 
>  Site Name
> 
>  Actual topology
> 
>  Indoor/Outdoor
> 
>  Actuel DC Load (A)
> 
>  DC power solution
> 
>  Gen Capacity (KVA)
> 
>  Main issue
> 
>  Action plan
> 
>  South West
> 
>  Mutenguene
> 
>  IHS_BUA_168
> 
>  MILE 4 Q10
> 
>  GRID GEN
> 
>  outdoor
> 
>  310
> 
>  HUAWEI 24kw 4 lithium Batt 6 rectifiers
> 
>  45KVA TRION
> 
>  old Generator loss compression
> 
>  30kva DG needed
> 
>  Cdt.